Files
skills-win/sim-rtl-flow/SKILL.md
T
2026-07-27 01:08:42 +08:00

17 KiB
Raw Blame History

name, description
name description
sim-rtl-flow Run the sim-rtl-flow LangGraph workflow at E:\LangGraph_Design\sim-rtl-flow — the Simulink-to-RTL-to-hardware design pipeline: Simulink -x principle sim (sim-golden) → HUMAN sign-off on simulation performance → optional -q fixed-point → parallel functional partition + RTL/SoC interface spec → HUMAN sign-off on the partition → per-module -E.slx nativization and Xilinx-IP replacement (parallel Send fanout) → Vivado build + timing → hardware-in-the-loop via fpga-imx6-flow or zynq-imx6-flow. It drives the compiled graph in-process (no langgraph dev server) and hands every subagent task back to THIS Claude session — and every human checkpoint to the USER — through a record/replay ledger stored in the design project being worked on. ALWAYS use this skill whenever the user wants to run, start, drive, resume or continue the sim-rtl-flow workflow / Simulink→RTL design flow, or says things like "启动 sim-rtl-flow", "跑 sim-rtl-flow", "运行仿真到RTL的设计流程", "执行 sim-rtl-flow 设计任务", "继续 sim-rtl-flow", "run the sim to rtl flow", "resume the sim-rtl-flow run", even if they don't name the project path. Also use it when the user asks to record a subagent result, to approve or reject one of the two human checkpoints, or to rehearse the graph with the scripted backend.

What this skill does

Drives the sim-rtl-flow graph (21 top-level nodes + a 3-node per-module subgraph, 1:1 with Notes/PR01-1.md, Notes/PR01-2.md and Notes/PR01_sim_rtl_flow.drawio).

The graph contains no agent logic — it talks to the outside world through two protocols: SubagentBackend (design work) and ReviewGate (the two mandatory human sign-offs). This skill plugs a record/replay implementation into both: the graph runs in-process until it needs an answer that isn't recorded yet, then stops and prints the request. You are the subagent; the USER is the reviewer. You do the work, record the answer, and resume — the driver replays the ledger, deterministically walks back to where it stopped, and asks for the next thing.

Item Value
Project root 见 ~\skills_env.md 的 SIM_RTL_FLOW_ROOT(driver 自动读取,也可 --project 覆盖)
Conda env langgraph (path 见 ~\skills_env.md 的 CONDA_LANGGRAPH_PYTHON;装环境用 /langgraph-vivado-install)
Graph sim_rtl_flow.graph:build_workflow (in-process, no langgraph dev)
Driver %USERPROFILE%\.claude\skills\sim-rtl-flow\scripts\run_sim_rtl_flow.py
Run state <work_dir>\.sim_rtl_flow\runs\<thread-id>\ — inside the design project, never in the workflow repo
Max attempts 10 per gate (default)

There is no LangGraph checkpointer in the driver, on purpose: graph nodes have no side effects of their own (all side effects live in the subagents, which are replayed), so re-invoking from scratch is cheaper and immune to partial-superstep resume semantics. ledger.json is the persistence.

Drive the driver with the Bash tool (Git Bash), not PowerShell — PowerShell 5.1 mangles the double quotes inside --result '{...}' payloads. Every command below was run this way and verified.

PY="<CONDA_LANGGRAPH_PYTHON — see ~\skills_env.md>"
RUN="$USERPROFILE/.claude/skills/sim-rtl-flow/scripts/run_sim_rtl_flow.py"
export PYTHONIOENCODING=utf-8

The driver resolves the workflow checkout from SIM_RTL_FLOW_ROOT in ~\skills_env.md, so no path is baked into this skill.

⚠️ The two human checkpoints are the user's decision, not yours

The graph stops at two points that an agent may not decide:

checkpoint where what the user confirms
sim_performance after step 1 the -x sim meets the requirement and may be frozen as sim-golden
functional_partition after step 3 the pure-sim / RTL / SoC split and the RTL↔SoC interface doc

When one comes up the driver prints a !!! banner. Relay the question and its context to the user verbatim, then wait. Do not approve on your own judgement, do not infer approval from "the numbers look fine", and do not use --all-ok (the driver refuses it for review keys anyway). A rejection must carry the user's reason.

"$PY" "$RUN" --work-dir <proj> --thread-id <id> record --key review:sim_performance#1 --approve
"$PY" "$RUN" --work-dir <proj> --thread-id <id> record --key review:sim_performance#1 \
  --reject --notes "带外抑制不足 6dB"

Rejecting sim_performance re-runs step 1; rejecting functional_partition re-runs the whole partition + interface superstep.

Non-negotiable design rules the graph enforces

From Notes/PR01.md and Notes/PR01-2.md; the graph routes on these.

  1. sim-golden is the only acceptance criterion. -q, the partition, and every -E version must match the -x sim. If it doesn't, record gate_passed: false — never record a pass you didn't verify.
  2. One -E.slx per RTL submodule, saved separately (<project>_A-E.slx, …). Do not nativize all submodules in one Simulink model.
  3. Never hand-edit MATLAB-generated RTL. If IP replacement, Vivado timing, or HIL needs a change there, return change_scope: "simulink_module" + affected_modules. The graph then forces a modify_e:* step — edit the -E.slx and re-simulate against sim-golden — before any RTL is regenerated.
  4. Timing fixes change the RTL, not the constraints. Prefer adding pipeline/delay stages. Only touch timing constraints when the constraint itself is plainly wrong, and say why in notes.
  5. HIL is strictly read-only. hil:* arrives with allow_code_changes=false. Run fpga-imx6-flow / zynq-imx6-flow for diagnosis only; the moment a code change is needed, stop that sub-flow and report it back here — the fix happens in the sim-rtl-flow main graph, then re-enters Vivado and HIL.

Run (agent path)

1. Write the workflow input

work_dir is the design project. All run state goes under <work_dir>/.sim_rtl_flow/ — that is where resume/record/status will look.

cat > /c/Users/Administrator/AppData/Local/Temp/claude/input.json <<'EOF'
{
  "requirements_path": "Notes/requirements.md",
  "work_dir": "E:/Xilinx_design/my_project",
  "project_name": "demo",
  "device_family": "fpga-imx6",
  "fixed_point_required": true,
  "rtl_modules": ["A", "B", "C"],
  "soc_modules": ["control"]
}
EOF
field meaning
requirements_path user's requirement .md, relative to work_dir
work_dir the design project — absolute path; also where run state is written
project_name artifact prefix — <name>-x.slx, <name>_A-E.slx, <name>.bit
device_family fpga-imx6 → HIL via fpga-imx6-flow; zynq-imx6 → zynq-imx6-flow. Anything else raises at initialize.
fixed_point_required false skips the -q stage
rtl_modules submodule names; each gets its own parallel native → ip_replace chain. Non-empty.
soc_modules MCU/SoC-side modules (interface-spec input)

2. Start — exits 10 with a handoff

"$PY" "$RUN" --thread-id my-design-001 start --input /c/Users/Administrator/AppData/Local/Temp/claude/input.json

start takes work_dir from the input JSON and prints where state landed. Verified:

work dir : E:\Xilinx_design\my_project
run dir  : E:\Xilinx_design\my_project\.sim_rtl_flow\runs\my-design-001
========================================================================
HANDOFF — 1 subagent task(s), 0 human review(s)
========================================================================
--- key: simulink_x#1
    role        : simulink-principle-agent
    permission  : WRITE ALLOWED
    prompt      : 根据需求文档创建或修订 Simulink -x 原理仿真;...

Exit codes: 10 = handoff pending, 0 = completed, 1 = failed, 2 = crash.

3. Answer, then resume

Every later command needs to find the run, so pass --work-dir (or cd into it):

W="--work-dir E:/Xilinx_design/my_project --thread-id my-design-001"
"$PY" "$RUN" $W record --key simulink_x#1 \
  --result '{"gate_passed": true, "artifacts": ["demo-x.slx"], "notes": "EVM -38dB"}'
"$PY" "$RUN" $W resume

Loop until WORKFLOW FINISHED — status: completed. When several keys are pending, record each, then resume once. record --all-ok fast-forwards pending subagent keys with a default success — rehearsal only, and it refuses review keys.

4. What you get handed

key what you actually do which skill to use
simulink_x#n build/revise the -x sim, document the performance envelope MATLAB MCP + model-based-design-core:building-simulink-models, simulating-simulink-models
review:sim_performance#n ask the user to sign off on sim-golden — (relay to user)
fixed_point#n -q fixed-point, compare to -x same MATLAB skills
partition#n pure-sim / RTL / SoC split, must not degrade sim-golden same
interfaces#n RTL↔SoC interface doc — register-config or data-stream only write the doc under work_dir
review:functional_partition#n ask the user to sign off on the split + interfaces — (relay to user)
module_plan#n split the RTL side into A/B/C…, give order + dependencies (first pass only) inline
native:<M>#n nativize M into HDL-capable blocks, save <project>_M-E.slx, generate RTL request says simulink-rtl-dev — not installed; use MATLAB MCP + model-based-design-core
ip_replace:<M>#n swap in Xilinx IP, cycle-true compare vs MATLAB RTL request says rtl-ip-replace — not installed; use vivado-sim + vivado-mcp
modify_e:vivado#n / modify_e:hil#n edit the named -E.slx and re-simulate against sim-golden MATLAB MCP + model-based-design-core
vivado#n build the Vivado project, synth+impl+bitstream, check all timing vivado-prj-create, vivado-mcp
hil:fpga-imx6-flow#n / hil:zynq-imx6-flow#n HIL debug, read-only fpga-imx6-flow / zynq-imx6-flow
timing_rework#n fix non-Simulink RTL / SoC / project timing inline
hil_rework#n apply the code change HIL asked for inline

#n is the n-th time that key has been requested this run — retries and rework produce #2, #3, …

5. Answer JSON

"$PY" "$RUN" schema prints both templates. All fields optional except approved.

subagent: {"success": true, "gate_passed": true, "artifacts": [], "notes": "",
           "timing_met": true, "hil_passed": true, "needs_code_change": false,
           "change_scope": "none", "affected_modules": [], "metadata": {}}
review:   {"approved": true, "notes": "", "metadata": {}}
field who reads it
success + gate_passed every design node — false → retry, then failed after 10 attempts
artifacts simulink_x's first artifact becomes sim-golden; vivado's go to HIL as the bitstream
timing_met vivado only
hil_passed hil:* only
needs_code_change + change_scope + affected_modules vivado and hil:* — the rework router

Routing on change_scope:

  • simulink_module → modify_e:* (edit -E.slx + re-simulate) → only the affected modules re-run native → ip_replace → Vivado → HIL.
  • non_simulink_rtl / soc / hardware → timing_rework (from Vivado) or hil_rework (from HIL) → Vivado.
  • The driver rejects needs_code_change: true with change_scope: "none".

6. Parallel batches (verified)

stage keys handed over at once
after -x / -q interfaces#1 and partition#1
module fanout one native:<M>#1 per module (3 for ["A","B","C"])
next module stage one ip_replace:<M>#1 per module

Work batched tasks in any order; record all, then resume.

Rehearsal without touching hardware

"$PY" "$RUN" dry-run --input examples/happy_path.json

Runs the whole graph against ScriptedBackend + auto-approving ScriptedReviewGate — no handoffs, no side effects. Verified: status: completed, 13 subagent calls listed with their skill and write permission, plus both review checkpoints. To rehearse a branch, add outcomes (task → list of results) and/or reviews (checkpoint → list of decisions) to the input JSON; start/resume strip both.

"outcomes": {"hil:fpga-imx6-flow": [
   {"success": true, "hil_passed": false, "needs_code_change": true,
    "change_scope": "simulink_module", "affected_modules": ["A"]},
   {"success": true, "hil_passed": true}]},
"reviews": {"sim_performance": [{"approved": false, "notes": "EVM 未达标"}]}

Other commands

"$PY" "$RUN" $W status                # ledger + pending + final status
"$PY" "$RUN" schema                   # both answer templates
"$PY" "$RUN" mermaid                  # graph as Mermaid (see gotcha)
"$PY" -m unittest discover -s tests   # project's own 16 tests — all pass

Global flags go before the subcommand: --project, --work-dir, --thread-id, --recursion-limit (200), --max-attempts (10).

Gotchas

  • resume/record/status need --work-dir (or a cd into the design project). Only start can infer it, from the input JSON. Without it the driver looks in the cwd and reports no input.json in ….
  • The driver refuses a work_dir inside the sim-rtl-flow repo. Run state belongs to the design project (PR01-2). examples/happy_path.json therefore carries a placeholder E:/Xilinx_design/your_project — fine for dry-run, but replace it before start.
  • mermaid output is still partly misleading. The forward and rework edges now render (path maps were added), but plan_modules' Send fanout is a dynamic edge Mermaid can't show. Use Notes/Result00.md for the authoritative picture.
  • --max-attempts must precede the subcommand and stay the same value across start and every resume — it is runtime context, not persisted state.
  • The two skills the graph names don't exist. native:* suggests simulink-rtl-dev, ip_replace:* suggests rtl-ip-replace; neither is installed. Fall back to the MATLAB MCP + model-based-design-core:* skills and vivado-sim / vivado-mcp. Don't abort.
  • simulink_x's first artifact silently becomes sim-golden. Record artifacts: [] and the graph substitutes <project_name>-x.slx. Always record the real filename.
  • module_plan runs only on the first pass. Rework rounds reuse the plan, so you will not be asked to re-partition the module list mid-run.
  • Re-recording a key requires editing ledger.json by hand. record only accepts currently-pending keys; anything already in the ledger is replayed forever. To redo a step, delete its entry and everything after it, then resume.
  • Runs created before the PR01-2 change live in the old location (<SIM_RTL_FLOW_ROOT>\runs\<id>\) and their ledgers have no review:* or module_plan keys, so they cannot be resumed under the current graph. Start a fresh thread instead.
  • work_dir is passed straight through to every subagent request. Forward slashes are fine on Windows; a relative "." resolves against wherever the driver was launched — always use an absolute path.
  • start wipes the ledger unless --keep-ledger. Use a fresh --thread-id per run.

Troubleshooting

symptom cause / fix
sim_rtl_flow package not found under …\src SIM_RTL_FLOW_ROOT in ~\skills_env.md is wrong/missing; fix it or pass --project <检出目录>
sim-rtl-flow 工作流仓库路径未配置 add SIM_RTL_FLOW_ROOT = <检出目录> to ~\skills_env.md
no input.json in …\.sim_rtl_flow\runs\<id> missing/incorrect --work-dir, or start was never run
nothing pending — run 'start' or 'resume' first the previous invoke completed or crashed; check status
--key X is not pending; pending = [...] typo, or already recorded (see the re-record gotcha)
--all-ok 不能用于人工审核断点 working as intended — the user must decide; use --approve / --reject
驳回必须写明理由:请提供 notes add --notes "<user's reason>"
unknown review fields: ['gate_passed'] you sent a subagent result to a review:* key; use --approve/--reject
needs_code_change=true requires an explicit change_scope add change_scope
MissingReviewGateError only if the graph is driven without a review gate — the driver always supplies one
device_family must be 'fpga-imx6' or 'zynq-imx6' raised in initialize; exit 2
exit 2 + recursion_limit a rework loop isn't converging — raise --recursion-limit, or stop recording needs_code_change for the same module
mojibake in the Chinese prompts export PYTHONIOENCODING=utf-8